小雪尝禁果又粗又大的视频_国产 在线 一区 二区_国产一区高跟丝袜在线_黄片免费观看在线无码_韩日欧美一级黄色片_天天摸日日摸狠狠添流水_欧美熟妇呻吟猛交XX性丨_七月丁香色婷婷综合激情_亚a∨国av综av涩涩涩_给我个免费看片bd

E510 series inverter

TECO Inverter E510 is a multi-functional vector inverter equipped with a 32-bit RISC processor and built-in PLC. It integrates safe stop (STO) and fire mode (Fire Mode). It can automatically adjust the carrier wave according to the operating temperature to reduce heat accumulation in the inverter. , the fan automatically detects temperature and starts, supports multiple communication protocols and copy modules, the operator can be pulled out, and complies with CE and UL safety certifications.

  • Brand :: TECO
  • Type:: E510

Multifunctional vector inverter, equipped with 32Bit RISC processor, built-in PLC, integrated safe stop (STO) and fire mode (Fire Mode), can automatically reduce the carrier according to the operating temperature, reduce heat accumulation in the inverter, and the fan automatically detects temperature Start, supports multiple communication protocols and copy modules, and the operator can be pulled out to comply with CE and UL safety certifications.


Features of TECO inverter E510: multifunctional universal inverter

TECO inverter E510 rated voltage and power range:

220V model

  • Power range: 0.4~15KW single/three-phase shared

  • Input voltage: 200V~240V

380V model

  • Power range: 0.75~18.5KW single

  • Input voltage: 380V~480V

  • Protection level: IP20

  • International certification: UL, CE

Features of TECO inverter E510:

  • Control method: vector control, v/f control

  • All series have built-in PLC for program control

  • All series have built-in rs-485 communication port (rj45)

  • The entire series has input and output phase loss protection functions

  • All series have input terminal counting function

  • Two analog inputs can be superimposed or acted independently

  • Unique low current detection function

  • Unique analog input monitoring function

  • Unique input and output terminal status display function makes control more convenient and faster

  • Unique fire mode settings

  • Parameters such as voltage, current, and frequency during alarm can be viewed to facilitate troubleshooting.


ModelVoltage
E510-2P5-H200-240V single three-phase
E510-2P5-H
E510-2P5-H1F200-240V single phase
E510-2P5-H1F
E510-401-H380-480V three phase
E510-402-H
E510-401-H1F
E510-402-H1F
E510-202-H200-240V single three-phase
E510-203-H
E510-202-H1F200-240V single phase
E510-203-H1F
E510-205-H3200-240V three phase
E510-403-H3380-480V three phase
E510-405-H3
E510-403-H3F
E510-405-H5F
E510-208-H3200-240V three phase
E510-210-H3
E510-408-H3/H3F380-480V three phase
E510-410-H3/H3F
E510-415-H3/H3F
E510-215-H3200-240V three phase
E510-220-H3
E510-420-H3/H3F380-480V three phase
E510-425-H3/H3F



Phone Number
Inquiry Form
E-Mail